Signal Controlled Sources
Description of the Signal Controlled Voltage Source and Signal Controlled Current Source components in Schematic Editor


Signal controlled sources (current and voltage) have electrical ports for connecting them with the electric circuit and a signal processing input port. The value of the sources is defined through that signal processing input.
The update rate of the sources will follow the execution rate of the signal processing control component or sub-circuit. It is recommended to use these sources whenever a slower update rate is acceptable (for example, for constant sources). In cases where a higher update rate is needed, consider using a Signal Controlled Sinusoidal Sources component.
Ports
- p node (electrical)
- Positive port.
- n node (electrical)
- Negative port.
- in
- Input for the voltage signal for the Signal Controlled Voltage Source component.
- Input for the current signal for the Signal Controlled Current Source component.
Properties
- Execution rate
- Execution rate of the signal processing control component or sub-circuit. More information about execution rates can be found in the Execution rates section.