Signal streaming

This section describes Signal streaming

Note: Signal streaming is ignored in TyphoonSim and changing its value will not affect TyphoonSim simulation at all.
Real-time only: This document is valid only for real-time/VHIL simulation.

Enabling Signal streaming property (on Probe or Digital probe component) allows acquisition and logging the signal at a medium sample rate. For a high sample rate Capture should be used, while for a low sample rate you should use the Read analog signals functionality.

Bandwidth

Signals can be streamed up to 512 KSPS for all execution rates. In case of over exceeded bandwidth, model can be changed to reduce number of streaming signals or increase SP execution rate.

Components

Signal streaming support Probe and Digital probe component Probe and Digital probe.

Table 1. Sinks component with Signal Streaming
sinks with Signal streaming
Probe
Digital Probe

HIL SCADA

Signal streaming data can be accessed in HIL SCADA over Stream data logger.

HIL API

Signal streaming data can be accessed in HIL API over add_data_logger() function.