Three Phase Doubly Fed Induction Machine
Description of the Three Phase Doubly Fed Induction Machine component in Schematic Editor.
component | component dialog window | component parameter |
---|---|---|
|
Electrical sub-system model
The electrical part of the machine is represented by the following system of equations, modeled in the stationary αβ reference frame. All rotor variables and parameters are referred to the stator by the turns ratio m.
If the saturation effects are considered, the equations have the same form, but in that case the magnetizing flux is a function of the magnetizing current:
where:
If the saturation effects and stator and rotor leakage fluxes are considered, the equations also have the same form, except in that case, the magnetizing flux is a function of the magnetizing current, the stator leakage flux is a function of the stator current, and the rotor leakage flux is a function of the rotor current:
where:
symbol | description |
---|---|
ψαs | Alpha axis component of the stator flux [Wb] |
ψβs | Beta axis component of the stator flux [Wb] |
ψαr | Alpha axis component of the rotor flux, referred to the stator [Wb] |
ψβr | Beta axis component of the rotor flux, referred to the stator [Wb] |
iαs | Alpha axis component of the stator current [A] |
iβs | Beta axis component of the stator current [A] |
iαr | Alpha axis component of the rotor current, referred to the stator [A] |
iβr | Beta axis component of the rotor current, referred to the stator [A] |
iαrr | Alpha axis component of the rotor current [A] |
iβrr | Beta axis component of the rotor current [A] |
vαs | Alpha axis component of the stator voltage [V] |
vβs | Beta axis component of the stator voltage [V] |
vαr | Alpha axis component of the rotor voltage, referred to the stator [V] |
vβr | Beta axis component of the rotor voltage, referred to the stator [V] |
vαrr | Alpha axis component of the rotor voltage [V] |
vβrr | Beta axis component of the rotor voltage [V] |
Rs | Stator phase resistance [Ω] |
Rr | Rotor phase resistance, referred to the stator [Ω] |
Lm | Magnetizing (mutual, main) inductance [H] |
Ls | Stator phase inductance [H] ( ) |
Lr | Rotor phase inductance, referred to the stator [H] ( ) |
ωr | Rotor electrical speed [rad/s] ( ) |
p | Machine number of pole pairs |
Te | Machine developed electromagnetic torque [Nm] |
m | Stator to rotor turns ratio |
ψm | Magnetizing flux [Wb] |
im | Magnetizing current [A] |
ψls | Stator leakage flux [H] |
is | Amplitude of the stator current [A] |
ψlr | Rotor leakage flux [H] |
ir | Amplitude of the rotor current [A] |
Mechanical sub-system model
Motion equation:
symbol | description |
---|---|
ωm | Rotor mechanical speed [rad/s] |
Jm | Combined rotor and load moment of inertia [kgm2] |
Te | Machine developed electromagnetic torque [Nm] |
Tl | Shaft mechanical load torque [Nm] |
b | Machine viscous friction coefficient [Nms] |
θm | Rotor mechanical angle [rad] |
Electrical
This component offers two levels of model fidelity, designated by the Model Type property. The following options are available:- linear
- nonlinear
- flux vs current
- absolute inductance vs current
symbol | description |
---|---|
Rs | Stator phase resistance [Ω] |
Rr | Rotor phase resistance, referred to the stator [Ω] |
Lls | Stator leakage inductance [H] |
Llr | Rotor leakage inductance, referred to the stator [H] |
Lm | Magnetizing (mutual, main) inductance [H] |
Saturable leakage inductance | If enabled, stator leakage inductance is a function of the stator current and rotor leakage inductance is a function of the rotor current |
is vector | List of instantaneous values of the stator current [A] |
Lls vector | List of the stator leakage inductance values [H] |
ir vector | List of instantaneous values of the rotor current [A] |
Llr vector | List of the rotor leakage inductance values [H] |
im vector | List of instantaneous values of the magnetizing current [A] |
psim vector | List of instantaneous values of the magnetizing flux [Wb] |
Lm vector | List of the magnetizing inductance values [H] |
m | Stator to rotor phase voltage ratio (turns ratio) |
- magnetizing flux vs magnetizing current
- magnetizing inductance vs magnetizing current
im_vector = [0.0, 0.661428, 0.957988, 1.224002, 1.527775, 1.836498, 2.485056, 3.197537, 4.162313, 5.57879, 8.211348, 12.342407, 22.172606]
psim_vector = [0.0, 0.125279, 0.192308, 0.25488, 0.318532, 0.382499, 0.511695, 0.635623, 0.76725, 0.885866, 1.007544, 1.097936, 1.186302]
im_vector = [0.00, 2.50, 5.00, 6.75, 7.50, 8.75, 11.50, 15.00, 20.00, 25.00]
Lm_vector = [0.00, 0.060648, 0.059024, 0.0561556, 0.054150667, 0.0495085714, 0.0404947826, 0.033212, 0.0265335, 0.0220932]
is_vector = [0.00, 1.88, 5.00, 10.00, 15.00, 20.00, 25.00, 30.00, 35.00, 40.00, 45.00, 50.00, 55.00, 60.00, 65.00, 70.00]
Lls_vector = [0.00, 0.0036010638, 0.00325, 0.002653, 0.00234667, 0.002166, 0.0020576, 0.00196733, 0.0018797142, 0.0018275, 0.001744889, 0.0016786, 0.001624545, 0.001579334, 0.00152030769, 0.0014698571]
ir_vector = [0.00, 1.88, 5.00, 10.00, 15.00, 20.00, 25.00, 30.00, 35.00, 40.00, 45.00, 50.00, 55.00, 60.00, 65.00, 70.00]
Llr_vector = [0.00, 0.0036010638, 0.00325, 0.002653, 0.00234667, 0.002166, 0.0020576, 0.00196733, 0.0018797142, 0.0018275, 0.001744889, 0.0016786, 0.001624545, 0.001579334, 0.00152030769, 0.0014698571]
Mechanical
symbol | description |
---|---|
pms | Machine number of pole pairs |
Star/delta | Stator winding connection (star or delta) |
Jm | Combined rotor and load moment of inertia [kgm2] |
Friction coefficient | Machine viscous friction coefficient [Nms] |
Unconstrained mechanical angle | Limiting mechanical angle between 0 and 2π |
Load
symbol | description |
---|---|
Load source | Load can be set from SCADA/external or from model (in model case, one signal processing input will appear) |
External/Model load type | External/Model load type: torque or speed |
Load ai pin | HIL analog input address for external torque command |
Load ai offset | Assigned offset value to the input signal representing external torque command |
Load ai gain | Assigned gain value to the input signal representing external torque command |
External load enables you to use an analog input signal from a HIL analog channel with the load_ai_pin address as an external torque/speed load, and to assign offset (V) and gain (Nm/V) to the input signal, according to the formula:
Feedback
symbol | description |
---|---|
Encoder ppr | Incremental encoder number of pulses per revolution |
Encoder Z pulse length | Z digital signal pulse length in periods. Can be Quarter length or Full period (default) |
Resolver pole pairs | Resolver number of pole pairs |
Resolver carrier source | Resolver carrier signal source selection (internal or external) |
External resolver carrier source type | External resolver carrier signal source type selection (single ended or differential); available only if the Resolver carrier source property is set to external |
Resolver carrier frequency | Resolver carrier signal frequency (internal carrier) [Hz] |
Resolver ai pin 1 | Resolver carrier input channel 1 address (external carrier) |
Resolver ai pin 2 | Resolver carrier input channel 2 address (external carrier); available only if the External resolver carrier source type property is set to differential |
Resolver ai offset | Resolver carrier input channel offset (external carrier) |
Resolver ai gain | Resolver carrier input channel gain (external carrier) |
Absolute encoder protocol | Standardized protocol providing the absolute machine encoder position |
If an external resolver carrier source is selected, the source signal type can be set as either single ended or differential. The single ended external resolver carrier source type enables use of an analog input signal from the HIL analog channel with the res_ai_pin_1 address as the external carrier source. Additionally, offset (V) and gain (V/V) values can be assigned to the input signal, according to the formula:
The differential external resolver carrier source type enables use of two analog input signals from the HIL analog channels with the res_ai_pin_1 and the res_ai_pin_2 addresses. Analog signals from these HIL analog inputs are subtracted, and the resulting signal is used as the external differential carrier source. Additionally, offset (V) and gain (V/V) values can be assigned to the input signal (similarly to the single ended case), according to the formula:
The following expression must hold in order to properly generate the encoder signals:
symbol | description |
---|---|
enc_ppr | Encoder number of pulses per revolution |
fm | Rotor mechanical frequency [Hz] |
Ts | Simulation time step [s] |
Advanced
symbol | description |
---|---|
Theta_ab | Position of the stationary αβ reference frame, in respect to the stator phase a axis [rad] |
The machine model output variables (currents, voltages and fluxes) can be observed from a stationary reference frame. There are two widely used approaches in electrical machine modeling: in the first, the alpha axis of the stationary reference frame lags by 90 degrees in regard to the stator phase a axis (used by default, and indicated in a) Figure 6. In the second one, the alpha axis is aligned with the stator phase a axis (indicated in b) Figure 6. The user can select between these two situations.
It is important to know the value of Theta_ab when the rotor position feedback is necessary. As an example, if a model uses the mechanical angle as a feedback signal and feeds it to one of the abc to dq, alpha beta to dq, dq to abc, or dq to alpha beta transformation blocks, the same transformation angle offset value should be used in both components to ensure the expected simulation results.
Snubber
All machines with current source based circuit interfaces have the Snubber tab in the properties window where the value of snubber resistance can be set. Snubbers are necessary in the cases when an inverter or a contactor is directly connected to the machine terminals. This value can be set to infinite (inf), but it is not recommended when a machine is directly connected to the inverter since there will be a current source directly connected to an open switch. In this case, one of each switch pairs S1 and S2, S3 and S4, and S5 and S6 will be forced closed by the circuit solver in order to avoid the topological conflicts. On the other hand, with finite snubber values, there's always a path for the currents Ia and Ib, so all inverter switches can be open in this case. Circuit representations of this circuit without and with snubber resistors are shown in Figure 4 and Figure 5 respectively. Snubbers are connected across the current sources.
symbol | description |
---|---|
Rsnb stator | Stator snubber resistance value [Ω] |
Rsnb rotor | Rotor snubber resistance value [Ω] |
Output
This block tab enables a single, vectorized signal output from the machine. The output vector contains selected machine mechanical and/or electrical variables in the same order as listed in this tab.
symbol | description |
---|---|
Execution rate | Signal processing output execution rate [s] |
Electrical torque | Machine electrical torque [Nm] |
Mechanical speed | Machine mechanical angular speed [rad/s] |
Mechanical angle | Machine mechanical angle [rad] |
Stator alpha axis current | Alpha axis component of the stator current [A] |
Stator beta axis current | Beta axis component of the stator current [A] |
Rotor alpha axis current | Alpha axis component of the rotor current, referred to the stator [A] |
Rotor beta axis current | Beta axis component of the rotor current, referred to the stator [A] |
Stator alpha axis flux | Alpha axis component of the stator flux [Wb] |
Stator beta axis flux | Beta axis component of the stator flux [Wb] |
Rotor alpha axis flux | Alpha axis component of the rotor flux, referred to the stator [Wb] |
Rotor beta axis flux | Beta axis component of the rotor flux, referred to the stator [Wb] |