Fiber Optic Input Card parametrization

Description of the set of parameters for the Fiber Optic Input Card in the HIL Connect Interface component.

Real-time only: This document is valid only for real-time simulation.

Parameters

Once you select a card, a series of parameters appear that allow you to describe the pins in your setup and how they are connected.

Table 1 lists possible parameters for connector X1. The first letter of the property "Name" differs depending on the Slot where the card is located. It can be derived by replacing s with: A, B, C, D, E, F, G, H.

Table 1. Description of X1 Connector parameters
Parameter Name Description
X1 sX01 Check if the X1 connector is used on Slot s on the HIL Connect
X1-1 sX01_1 Select if pin 1 of the X1 connector on Slot s is connected or not.
X1-2 sX01_2 Select if pin 2 of the X1 connector on Slot s is connected or not.
X1-3 sX01_3 Select if pin 3 of the X1 connector on Slot s is connected or not.
X1-4 sX01_4 Select if pin 4 of the X1 connector on Slot s is connected or not.
X1-5 sX01_5 Select if pin 5 of the X1 connector on Slot s is connected or not.
X1-6 sX01_6 Select if pin 6 of the X1 connector on Slot s is connected or not.
X1-7 sX01_7 Select if pin 7 of the X1 connector on Slot s is connected or not.
X1-8 sX01_8 Select if pin 8 of the X1 connector on Slot s is connected or not.
X1-9 sX01_9 Select if pin 9 of the X1 connector on Slot s is connected or not.
X1-10 sX01_10 Select if pin 10 of the X1 connector on Slot s is connected or not.
X1-11 sX01_11 Select if pin 11 of the X1 connector on Slot s is connected or not.
X1-12 sX01_12 Select if pin 12 of the X1 connector on Slot s is connected or not.
X1-13 sX01_13 Select if pin 13 of the X1 connector on Slot s is connected or not.
X1-14 sX01_14 Select if pin 14 of the X1 connector on Slot s is connected or not.
X1-15 sX01_15 Select if pin 15 of the X1 connector on Slot s is connected or not.
X1-16 sX01_16 Select if pin 16 of the X1 connector on Slot s is connected or not.

Ports

Signals from the digital inputs of the HIL Connect can be accessed through the following output port of the HIL Connect Interface component (again, the first letter depends on the Slot where this card is located):

  • sX1

As internal digital probes already exist, these ports can be used for sourcing signals inside of the model. The output of this port is a vector with the length of 16 elements, where each element of that vector corresponds to one pin of the connector.