IO Timing
Sample rates and timing details for HIL606 devices
IO Timing Details
All analog IOs are updated/sampled at the beginning of each simulation time step (t1), which is software defined. To improve the PWM sampling resolution, digital inputs actually are sampled at a higher rate (t2), independent of the simulation time step value. Similarly, digital outputs are updated at a higher t2 rate. For overall expected loop-back latency, please consult Loopback Latency.

Symbol | Parameter | Value |
---|---|---|
t1 | Simulation step | Software defined |
t2 | Digital input sampling time | 280 MSPS |
IO class | Sample/Update rate | Comment |
---|---|---|
Digital input | 280 MSPS | All digital inputs are sampled simultaneously. |
Digital output | Up to 280 MSPS | All digital outputs are updated simultaneously. |
Analog input | 1/t1 | All analog inputs are sampled simultaneously. Minimum sample time is 1 μs. |
Analog output | 1/t1* | All analog outputs are updated simultaneously. |
* Valid for all simulation timesteps except 200 ns; in this case, all analog outputs are updated on every other time step (400 ns).
IO class | HIL606 |
---|---|
Digital output (Tdo) | 150 ns |
Analog output (Tao) | 340 ns |